Table of
Contents
1.
Definitions and Scope
1.1. A Home inspection is a non-invasive visual
examination of a residential dwelling, performed
for a fee, which is designed to identify observed
material defects within specific components of
said dwelling. Components may include any combination
of mechanical, structural, electrical, plumbing,
or other essential systems or portions of the
home, as identified and agreed to by the Client
and Inspector, prior to or during the inspection
process.
I. A home inspection is intended to assist
in evaluation of the overall condition of the
dwelling. The inspection is based on observation
of the visible and apparent condition of the
structure and its components on the date of
the inspection and not the determination of
future conditions.
II. A home inspection will not reveal every
problem that exists or ever could exist, but
only those material defects observed on the
day of the inspection.
1.2. A Material defect is a problem with
a residential real property or any portion of
it that would have a significant adverse impact
on the value of the property or that involves
an unreasonable risk to people on the property.
The fact that a structural element, system or
subsystem is near, at or beyond the end of the
normal useful life of such a structural element,
system or subsystem is not by itself a material
defect.
1.3. An Inspection report shall describe
and identify in written format the inspected
systems, structures, and components of the dwelling
and shall identify material defects observed.
Inspection reports may contain recommendations
regarding conditions reported or recommendations
for correction, monitoring or further evaluation
by professionals.
2.
Standards of Practice
2.1.
Roof
I. The inspector shall inspect from ground
level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney
and other roof penetrations.
E. The general structure of the roof from the
readily accessible panels, doors or stairs.
II. The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage
pipes.
D. Remove snow, ice, debris or other conditions
that prohibit the observation of the roof surfaces.
E. Inspect antennae, lightning arresters, or
similar attachments.
2.2.
Exterior
I. The inspector shall inspect:
A. The flashing and trim.
B. All exterior doors, decks, stoops, steps,
stairs, porches, railings, eaves, soffits, fascias,
grading, and walkways.
C. And report as in need of repair any spacings
between intermediate balusters, spindles, or
rails for steps, stairways, balconies, and railings
that permit the passage of an object greater
than four inches in diameter.
D. The vegetation, surface drainage and retaining
walls when these are likely to adversely affect
the building.
E. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm windows,
shutters, awnings, fences, outbuildings, or
exterior accent lighting.
B. Inspect items, including window and door
flashings, which are not visible or readily
accessible from the ground.
C. Inspect geological, geotechnical, or hydrological
conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization
measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window
seals or damaged glass.
2.3.
Basement, Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. Any present conditions or indications of
active water penetration by probing a representative
sampling of structural components where deterioration
is believed to be present or where clear indications
of deterioration are present.
F. And report any general indications of foundation
movement that are observed, such as but not
limited to sheetrock cracks, brick cracks, out-of-square
door frames or floor slopes.
II. The inspector is not required to:
A. Enter any crawlspaces that are not readily
accessible or where entry could cause damage
or pose a hazard to the inspector in his or
her opinion.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or
adequacy of foundation bolting, bracing, joists
or support systems.
E. Provide any engineering or architectural
service.
F. Report on the adequacy of any structural
system or component.
2.4.
Heating
I. The inspector shall inspect:
A. The heating system and describe the energy
source and heating method using normal operating
controls.
B. And report as in need of repair electric
furnaces which do not operate.
C. And report if inspector deemed the furnace
inaccessible.
II. The inspector is not required to:
A. Inspect or evaluate interiors of flues
or chimneys, fire chambers, the heat exchanger,
the humidifier or dehumidifier, the electronic
air filter, solar heating systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow,
balance, distribution, size, capacity, BTU,
or supply adequacy of the heating system.
D. Light pilot flames.
E. Activate heating, heat pump systems, or other
heating systems when ambient temperatures or
other circumstances are not conducive to safe
operation or may damage the equipment.
F. Operate electronic thermostats.
G. Evaluate fuel quality.
2.5.
Cooling
I. The inspector shall inspect:
A. The central cooling equipment using normal
operating controls.
II. The inspector is not required to:
A. Determine the uniformity, temperature,
flow, balance, distribution, size, capacity,
BTU, or supply adequacy of the cooling system.
B. Inspect window units, through-wall units,
or electronic air filters.
C. Operate equipment or systems if exterior
temperature is below 60 degrees Fahrenheit or
when other circumstances are not conducive to
safe operation or may damage the equipment.
D. Inspect or determine thermostat calibration,
heat anticipation or automatic setbacks or clocks.
E. Examine electrical current, coolant fluids
or gasses, or coolant leakage.
2.6.
Plumbing
I. The inspector shall:
A. Inspect the main water shut off valve.
B. Inspect the water heating equipment, including
combustion air, venting, connections, energy
sources, seismic bracing, and verify the presence
or absence of temperature-pressure relief valves
and/or Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including
all fixtures and faucets.
F. Inspect the drain, waste and vent systems,
including all fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps testing sumps
with accessible floats.
I. Inspect and describe the water supply, drain,
waste and main fuel shut-off valves, as well
as the location of the water main and main fuel
shut-off valves.
J. Inspect and determine if the water supply
is public or private.
K. Inspect and report as in need of repair deficiencies
in the water supply by viewing the functional
flow in two fixtures operated simultaneously.
L. Inspect and report as in need of repair deficiencies
in installation and identification of hot and
cold faucets.
M. Inspect and report as in need of repair mechanical
drain-stops that are missing or do not operate
if installed in sinks, lavatories and tubs.
N. Inspect and report as in need of repair commodes
that have cracks in the ceramic material, are
improperly mounted on the floor, leak, or have
tank components which do not operate.
II. The inspector is not required to:
A. Light pilot flames.
B. Determine the size, temperature, age, life
expectancy or adequacy of the water heater.
C. Inspect interiors of flues or chimneys, water
softening or filtering systems, well pumps or
tanks, safety or shut-of valves, floor drains
or sprinkler systems.
D. Determine the exact flow rate, volume, pressure,
temperature, or adequacy of the water supply.
E. Determine the water quality or potability
or the reliability of the water supply or source.
F. Open closed plumbing access panels.
G. Inspect clothes washing machine connections.
H. Operate any main, branch or fixture valve
except fixture faucets and hose faucets attached
to the building.
I. Test shower pans, tub and shower surrounds
or enclosures for leakage.
J. Evaluate the compliance with local or state
conservation or energy standards, or the proper
design or sizing of any water, waste or venting
components, fixtures or piping.
K. Determine the effectiveness of anti-siphon,
back-flow prevention or drain-stop devices.
L. Determine whether there are sufficient clean-outs
for effective cleaning of drains.
M. Evaluate gas, liquid propane or oil storage
tanks.
N. Excavate or otherwise uncover the private
sewage system or its components to determine
size, adequacy or efficiency.
O. Inspect water treatment systems or water
filters.
P. Inspect pressure pumps or bladder tanks.
Q. Evaluate time to obtain hot water at fixtures,
or perform testing of any kind to water heater
elements.
R. Evaluate or determine the adequacy of combustion
air.
S. Test, operate, open or close Watts 210 valves
and/or TPR valves.
T. Examine ancillary systems or components,
such as, but not limited to, those relating
to solar water heating, hot water circulation.
2.7.
Electrical
I. The inspector shall inspect:
A. The service line.
B. The meter box.
C. The main disconnect.
D. And determine the service amperage.
E. Panels, breakers and fuses.
F. The grounding.
G. The bonding.
H. A representative sampling of switches, receptacles,
light fixtures, and test all GFCI receptacles
and GFCI circuit breakers observed and deemed
to be GFCI's during the inspection.
I. And report the presence of solid conductor
aluminum branch circuit wiring if readily visible.
J. And report on any GFCI-tested receptacles
in which power is not present, polarity is incorrect,
the receptacle is not grounded, is not secured
to the wall, the cover is not in place, the
ground fault circuit interrupter devices are
not properly installed or do not operate properly,
or evidence of arcing or excessive heat is present.
K. The service entrance conductors and the condition
of their sheathing.
L. The ground fault circuit interrupters with
a GFCI tester.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in
need of repair deficiencies in the integrity
of the insulation, drip loop, or separation
of conductors at weatherheads and clearances.
II. The inspector is not required to:
A. Insert any tool, probe or device into
the main or sub-panels.
B. Operate electrical systems that are shut
down.
C. Remove panel covers or dead front covers
if not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage
of the main service if not visibly labeled.
G. Inspect the alarm system and components.
H. Inspect the ancillary wiring.
I. Activate any electrical systems or branch
circuits which are not energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical de-icing
tapes, swimming pool wiring or any time-controlled
devices.
L. Verify the continuity of the connected service
ground.
M. Inspect private or emergency electrical supply
sources, including but not limited to generators,
windmills, photovoltaic solar collectors, or
battery or electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct drop voltage calculations.
P. Determine the accuracy of breaker labeling.
2.8.
Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and close the
damper door if readily accessible and operable.
B. Hearth extensions and other permanently installed
components.
C. And report as in need of repair deficiencies
in the lintel, hearth and material surrounding
the fireplace, including clearance from combustible
materials
II. The inspector is not required to:
A. Inspect the vent system.
B. Inspect the interior of the chimney or flue,
fire doors or screens, seals or mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion make up devices.
I. Inspect heat distribution assists whether
gravity controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox
contents.
M. Determine adequacy of draft, perform a smoke
test or dismantle or remove any component.
2.9.
Attic, Ventilation & Insulation
I. The inspector shall inspect:
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or lack
of insulation.
II. The inspector is not required to:
A. Enter the attic or unfinished spaces
that are not readily accessible or where entry
could cause damage or pose a safety hazard to
the inspector in his or her opinion.
B. To move or touch insulation.
C. To move or touch vapor retarders.
D. Break or otherwise damage the surface finish
or weather seal on or around access panels and
covers.
E. Identify the composition or the exact R-value
of insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in
insulation/wrapping of pipes, ducts, jackets,
boilers, and wiring.
2.10.
Doors, Windows & Interior
I. The inspector shall:
A. Open and close a representative number
of doors and windows.
B. Inspect the walls, ceilings, steps, stairways,
and railings.
C. Inspect garage doors and garage door openers
by operating first by remote (if available)
and then by the installed automatic door control.
D. And report as in need of repair any installed
electronic sensors that are not operable or
not installed at proper heights above the garage
door.
E. And report as in need of repair any door
locks or side ropes that have not been removed
or disabled when garage door opener is in use.
F. And report as in need of repair any windows
that are obviously fogged or display other evidence
of broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window treatments
or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing in locations subject
to human impact.
D. Inspect security components.
E. Evaluate the fastening of countertops, cabinets,
sink tops and fixtures, or firewall compromises.
F. Move furniture, stored items, or any coverings
like carpets or rugs in order to inspect the
concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances.
I. Inspect or operate equipment housed in the
garage except as otherwise noted.
J. Verify or certify safe operation of any auto
reverse or related safety function of a garage
door.
K. Operate or evaluate security bar release
and opening mechanisms, whether interior or
exterior, including compliance with local, state,
or federal standards.
L. Operate any system, appliance or component
that requires the use of special keys, codes,
combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles
or signal lights.
N. Determine leakage from microwave ovens.
O. Operate or examine any sauna, steam-jenny,
kiln, toaster, ice-maker, coffee-maker, can-opener,
bread-warmer, blender, instant hot water dispenser,
or other small, ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable,
freestanding, or otherwise non-permanently installed
pool/spa or self-contained equipment.
U. Come into contact with any pool or spa water
in order to determine the system structure or
components.
V. Determine the adequacy of spa jet water force
or bubble effect.
W. Determine the structural integrity or leakage
of a pool or spa.
3. Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An inspection is not technically exhaustive.
II. An inspection will not identify concealed
or latent defects.
III. An inspection will not deal with aesthetic
concerns or what could be deemed matters of
taste, cosmetic, etc.
IV. An inspection will not determine the suitability
of the property for any use.
V. An inspection does not determine the market
value of the property or its marketability.
VI. An inspection does not determine the advisability
or inadvisability of the purchase of the inspected
property.
VII. An inspection does not determine the life
expectancy of the property or any components
or systems therein.
VIII. An inspection does not include items not
permanently installed.
IX. These Standards of Practice apply only to
homes with four or fewer dwelling units.
3.2.
Exclusions:
I. The inspectors are not required to determine:
A. Property boundary lines or encroachments.
B. The condition of any component or system
that is not readily accessible.
C. The service life expectancy of any component
or system.
D. The size, capacity, BTU, performance, or
efficiency of any component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement
of any system or component.
G. Future conditions.
H. The compliance with codes or regulations.
I. The presence of evidence of rodents, animals
or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including,
but not limited to, the presence of lead in
paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or conformance with
manufacturer installation or any information
included in the consumer protection bulletin.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of how much it will cost to run
any given system.
II. The inspectors are not required to operate:
A. Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical systems
such as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the
use of normal operating controls.
E. Any shut off valve.
F. Any electrical disconnect or over current
protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar
equipment.
III. The inspectors are not required to:
A. Move any personal items or other obstructions,
such as, but not limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any system
or component.
C. Enter or access any area which may, in the
opinion of the inspector, to be unsafe or risk
personal safety.
D. Enter crawlspaces or other areas that are
unsafe or not readily accessible.
E. Inspect underground items such as, but not
limited to, underground storage tanks or other
indications of their presence, whether abandoned
or actively used.
F. Do anything which, in the inspector's opinion,
is likely to be unsafe or dangerous to the inspector
or others or damage property, such as, but not
limited to, walking on roof surfaces, climbing
ladders, entering attic spaces or negotiating
with dogs.
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit
housing.
I. Inspect intercoms, speaker systems, radio-controlled,
security devices or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional
service other than home inspection.
M. Research the history of the property, report
on its potential for alteration, modification,
extendibility, or its suitability for a specific
or proposed use for occupancy.
N. Determine the age of construction or installation
of any system structure, or component of a building,
or differentiate between original construction
or subsequent additions, improvements, renovations
or replacements thereto.
O. Determine the insurability of a property.
4.
Glossary of Terms
4.1. Accessible: Can be approached or entered
by the inspector safely, without difficulty,
fear or danger.
4.2. Activate: To turn on, supply power,
or enable systems, equipment, or devices to
become active by normal operating controls.
Examples include turning on the gas or water
supply valves to the fixtures and appliances
and activating electrical breakers or fuses.
4.3. Adversely Affect: Constitute, or potentially
constitute, a negative or destructive impact.
4.4. Alarm System: Warning devices, installed
or free-standing, including but not limited
to: Carbon monoxide detectors, flue gas and
other spillage detectors, security equipment,
ejector pumps and smoke alarms.
4.5. Appliance: A household device operated
by use of electricity or gas. Not included in
this definition are components covered under
central heating, central cooling or plumbing.
4.6. Architectural Service: Any practice
involving the art and science of building design
for construction of any structure or grouping
of structures and the use of space within and
surrounding the structures or the design, design
development, preparation of construction contract
documents, and administration of the construction
contract.
4.7. Component: A permanently installed
or attached fixture, element or part of a system.
4.8. Condition: The visible and conspicuous
state of being of an object.
4.9. Crawlspace: The area within the confines
of the foundation and between the ground and
the underside of the lowest floor structural
component.
4.10. Decorative: Ornamental; not required
for the operation of essential systems and components
of a home.
4.11. Describe: Report in writing a system
or component by its type, or other observed
characteristics, to distinguish it from other
components used for the same purpose.
4.12. Determine: To arrive at an opinion
or conclusion pursuant to examination.
4.13. Dismantle: To open, take apart or
remove any component, device or piece that would
not typically be opened, taken apart or removed
by an ordinary occupant.
4.14. Engineering Service: Any professional
service or creative work requiring engineering
education, training, and experience and the
application of special knowledge of the mathematical,
physical and engineering sciences to such professional
service or creative work as consultation, investigation,
evaluation, planning, design and supervision
of construction for the purpose of assuring
compliance with the specifications and design,
in conjunction with structures, buildings, machines,
equipment, works or processes.
4.15. Enter: To go into an area to observe
all visible components.
4.16. Evaluate: To assess the systems, structures
or components of a dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the
structure or wall rests; usually masonry, concrete,
or stone, and generally partially underground.
4.19. Function: The action for which an
item, component, or system is specially fitted
or used or for which an item, component or system
exists; to be in action or perform a task.
4.20. Functional: Performing, or able to
perform, a function.
4.21. Home Inspection: The process by which
an inspector visually examines the readily accessible
systems and components of a home and operates
those systems and components utilizing these
Standards of Practice as a guideline.
4.22. Household Appliances: Kitchen and
laundry appliances, room air conditioners, and
similar appliances.
4.23. Inspect: To visually look at readily
accessible systems and components safely, using
normal operating controls and accessing readily
accessible panels and areas.
4.24. Inspected Property: The readily accessible
areas of the buildings, site, items, components,
and systems included in the inspection.
4.25. Inspector: One who performs a real
estate inspection.
4.26. Installed: Attached or connected such
that the installed item requires tool for removal.
4.27. Material Defect: Refer to section
1.2.
4.28. Normal Operating Controls: Devices
such as thermostats that would be operated by
ordinary occupants which require no specialized
skill or knowledge.
4.29. Observe: To see through visually directed
attention.
4.30. Operate: To cause systems to function
or turn on with normal operating controls.
4.31. Readily Accessible: An item or component
is readily accessible if, in the judgment of
the inspector, it is capable of being safely
observed without movement of obstacles, detachment
or disengagement of connecting or securing devices,
or other unsafe or difficult procedures to gain
access.
4.32. Recreational Facilities: Spas, saunas,
steam baths, swimming pools, tennis courts,
playground equipment, and other exercise, entertainment
or athletic facilities.
4.33. Report: A written communication (possibly
including digital images) of any material defects
seen during the inspection.
4.34. Representative Number: A sufficient
number to serve as a typical or characteristic
example of the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated
glass, or rigid plastic.
4.36. Shut Down: Turned off, unplugged,
inactive, not in service, not operational, etc.
4.37. Structural Component: A component
which supports non-variable forces or weights
(dead loads) and variable forces or weights
(live loads).
4.38. System: An assembly of various components
to function as a whole.
4.39. Technically Exhaustive: A comprehensive
and detailed examination beyond the scope of
a real estate home inspection which would involve
or include, but would not be limited to: dismantling,
specialized knowledge or training, special equipment,
measurements, calculations, testing, research,
analysis or other means.
4.40. Unsafe: A condition in a readily accessible,
installed system or component which is judged
to be a significant risk of personal injury
during normal, day-to-day use. The risk may
be due to damage, deterioration, improper installation
or a change in accepted residential construction
standards.
4.41. Verify: To confirm or substantiate.
|